EasyManuals Logo

AUMA SA Series Operation Instructions

AUMA SA Series
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
275.2.2. Cable connection
295.2.3. Terminal compartment (for mains connection): close
305.2.4. HART terminal compartment: open (version with HART connection board)
315.2.5. HART cables: connect
335.2.6. HART terminal compartment: close (version with HART connection board)
345.3. Accessories for electrical connection
345.3.1. Controls mounted on wall bracket
355.3.2. Parking frame
355.3.3. DS intermediate frame for double sealing
365.3.4. External earth connection
376. Operation................................................................................................................................
376.1. Manual operation
376.1.1. Engage manual operation
376.1.2. Manual operation: disengage
386.2. Motor operation
386.2.1. Local actuator operation
396.2.2. Actuator operation from remote
396.3. Menu navigation via push buttons (for settings and indications)
406.3.1. Menu layout and navigation
416.4. User level, password
416.4.1. Password entry
426.4.2. Password change
426.5. Language in the display
436.5.1. Language change
447. Indications..............................................................................................................................
447.1. Indications during commissioning
447.2. Indications in the display
457.2.1. Feedback indications from actuator and valve
487.2.2. Status indications according to AUMA classification
487.2.3. Status indications according to NAMUR recommendation
507.3. Indication lights of local controls
517.4. Optional indications
517.4.1. Mechanical position indication (self-adjusting)
517.4.2. Mechanical position indication via indicator mark
528. Signals (output signals).........................................................................................................
528.1. Signals via HART
528.2. Status signals via output contacts (digital outputs)
528.2.1. Assignment of outputs
528.2.2. Coding the outputs
528.3. Analogue signals (analogue outputs)
539. Commissioning (basic settings)...........................................................................................
539.1. Type of seating: set
549.2. Torque switching: set
559.3. Limit switching: set
579.4. HART address (slave address): set
589.5. Test run
589.5.1. Direction of rotation at mechanical position indicator: check
599.5.2. Direction of rotation at hollow shaft/stem: check
609.5.3. Limit switching: check
3
SA 07.2 SA 16.2/SAR 07.2 SAR 16.2 Control unit: electronic (MWG)
AC 01.2 Non-Intrusive HART Table of contents

Table of Contents

Other manuals for AUMA SA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUMA SA Series and is the answer not in the manual?

AUMA SA Series Specifications

General IconGeneral
Torque range10 Nm to 32, 000 Nm
Protection classIP68
Ambient temperature+70°C
Voltage24V DC
CommunicationPROFIBUS DP, MODBUS RTU, Foundation Fieldbus
CertificationsATEX, IECEx, CSA, GOST, SIL
ControlLocal, Remote, Bus (PROFIBUS, MODBUS)

Related product manuals