5.2.3. Terminal compartment: close
Figure 16: Close terminal compartment
[1] Cover
[2] Screws for cover
[3] O-ring
[4] Blanking plugs
[5] Cable gland
[6] Frame
1. Clean sealing faces of cover [1] and frame [6].
2. Preserve joint surfaces with an acid-free corrosion protection agent.
3. Check whether O-ring [3] is in good condition, replace if damaged.
4. Apply a thin film of non-acidic grease to the O-ring and insert it correctly.
Flameproof enclosure, danger of explosion!
Risk of death or serious injury.
Handle cover and housing parts with care.
Joint surfaces must not be damaged or soiled in any way.
Do not jam cover during fitting.
5. Fit cover [1] and fasten screws [2] evenly crosswise.
5.3. Accessories for electrical connection
5.3.1. Parking frame
Option
Application
Parking frame for safe storage of a disconnected plug.
For protection against touching the bare contacts and against environmental influences.