31
Digital Gauge Mode – displays the parameters in form of a digital gauge
graph.
Full Screen Display – this option is only available in the waveform graph
mode, and mostly used in Graph Merge status for data comparison. There
are three control buttons available on the top right side of the screen under
this mode.
Edit Button – tap to open an edit window, on which you can set the
waveform color and the line thickness displayed for the selected
parameter item.
Scale Button – tap to change the scale values, which are displayed below
the waveform graph. There are four scales available: x1, x2, x4 and x8.
Zoom-out Button – tap to exit full screen display.
To edit the waveform color and line thickness in a data graph
1. Select 1 to 3 parameter items to display in Waveform Graph mode.
2. Tap the Zoom-in Button on the right to display the data graph in full
screen.
3. Tap the Edit Button, an edit window displays.
4. Select a parameter item on the left column.
5. Select a desired sample color from the second column.
6. Select a desired sample line thickness from the right column.
7. Repeat steps 4-6 to edit the waveform for each parameter item.
8. Tap Done to save the setting and exit, or tap Cancel to exit without saving.
4. Functional Buttons
The operations of all the available functional buttons on the Live Data screen
are described below:
Back – returns to the previous screen or exit the function.
Record – starts recording the retrieved live data; the recorded data is then
stored as a video clip in the Data Manager application for future reviews.
This function could be triggered automatically at preset threshold value or
manually as you choose, and the triggering mode and record duration can
be configured in the Setting mode of Live Data.
Freeze – displays the retrieved data in freeze mode.
Previous Frame – moves to the previous frame in the freeze data.
Next Frame – moves to the next frame in the freeze data.
Resume – this button displays when the Record or Freeze function is
applied. Tapping this button stops data recording, or exits freeze data
mode, and resumes normal data display mode.