PARTNER
®
Advanced Communications System Installation, Programming, and Use
Backup and Restore
4-6
3. To change the setting, press
D or d until the setting you want appears, or press
r to return the setting to the factory setting. The possible settings are:
■ 1 = Active Internal
■ 2 = Active PC Card
■ 3 = Not Active (the factory setting)
■ 4 = Backup Alarm Cleared
4. Exit programming mode.
For information about using Option 3, Backup Alarm Cleared, see “Clearing a Backup-Failure
Alarm” on page 11-4.
Backup Programming—Manual (#124) 4
Use this feature to manually back up all the programming (except the system date and time) to
either the internal memory of the processor module or a Backup/Restore PC Card.
Programming 4
To begin a manual backup of system settings:
1. If you want to back up to a PC Card, verify that only one Backup/Restore Card is in the
processor module. If you do not have a PC Card installed, see “Using a PC Card” on page
10-2 or refer to the PARTNER PC Card Installation Instructions that came with your PC Card.
2. Press
f00ss#124 at extension 10 or 11.
The current setting appears.
3. To change the setting, press
D or d until the setting you want appears, or press
r to return the setting to the factory setting. The possible settings are:
■ 1 = Internal Memory (the factory setting)
■ 2 = PC Card
If there is a problem, one of the following messages appears (see Chapter 11,
“Troubleshooting” for explanations and corrective actions):
■ Memory Error
■ Insert Valid Card
■ SystemBusy
If there is no problem, press Enter to begin the backup.