Installation
The 1600 DSL Module
2-25
Programming Connections for the 1600 DSL Module 2
Initial Configuration of the 1600 DSL Module 2
Remote administration of the 1600 DSL module is available through the PARTNER ACS R7.0 PC
Administration software. You must have the following:
■ Release 5.0 or later software on the 1600 DSL module
■ Release 7.0 software version of PARTNER ACS
■ PARTNER ACS R7.0 PC Administration software
For more information, see the PARTNER
®
ACS R7.0 PC Administration Getting Started.
The programming of the 1600 DSL module is
separate from the programming of the PARTNER
ACS. You can program the 1600 DSL module either
locally or remotely.
To locally program the module, connect a cable from
a PC’s serial port to the Console port on the module.
You can set up the module for remote programming
by following these steps (see Figure ):
1. Connect a cable from an extension port on the
system to the Line jack on an external modem.
The modem should have the following
parameters:
■ 14.4 kbps or greater
■ Auto-Answer is enabled
■ DTR override is enabled
■ Echo commands are Suppressed
■ Result and Error codes are Suppressed
2. Connect a cable from the serial port on the
modem to a null modem.
3. Connect a cable from the null modem to the
Console port on the 1600 DSL module.
Figure 2-23. Remote Programming
Setup
Tip/Ring
Extension Port
1600 DSL Module
Console Port
External Modem
Null Modem
PARTNER ACS