AXIS P5512 PTZ Dome Network Camera
System Options
Uploaded les are accessed through http://<ip address>/local/<user>/<file name> where <user> is the
selected user group (viewer, operator or administrator) for the uploaded le.
Plain Cong
Plain Cong is for advanced users with experience of Axis product conguration. All parameters can be set and modied from this
page. H elp is available from the standard help pages.
To open Plain Cong, go to System Options > Advanced > Plain Cong.
Reset t o factory default settings
This will reset all parameters, including the I P addres s, to the factory default settings:
1. Press and hold the Control button and the Restart button at the same time (see Hardware overview, on page 4 ).
2. Release the Restart button but continue to hold down the Control button for about 15 seconds until the Status indicator
ashes amber.
3. Release the Control button. The pro cess is complete after about 1 minute (when the Status indicator turns green). The
product has been reset to the factory default settings. The default IP address is 192.168.0.90
4. Re-assign the IP address.
It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance.