52
DISPLAY (DP C01.RS232.7)
DEALER MANUAL MAX DRIVE SYSTEM
flash for 4 seconds, indicating that maintenance
is necessary.
• The maintenance alert function can be disabled:
settings
➞ maintenance alert (MA) ➞ main-
tenance alert (MA) ➞ 0. (Maintenance alert
can also be set via a computer. This requires a
USB connection. See also the parameter setting
instructions).
6.5.9 Further Settings:
Password Setting
When the speed field displays PSd, it is a prompt to
enter a password. Press / to set the four-figure
password (using digits 0 to 9). Briefly press to
switch between the single digits of the password. The
default password is "0512". Briefly press to switch
between the single digits of the password. The default
password is "0512". Briefly press to confirm
your setting. If the set password is wrong, the system
automatically returns to the previous interface. If the
set password is correct, the system will switch to the
setting of the wheel diameter.
6.5.10 Wheel Diameter Selection
When the speed position displays Wd, press / to
select the correct wheel diameter: 16/18/20/ 22/24/26,
700c, 28/29. The measurements are in inches. A wrong
wheel diameter can lead to speed anomalies.
After this setting, briefly press
(< 0.3 seconds) to
enter the setting interface of speed limit.