Receiving & Installation 3-13
MN1276
X3 Digital Inputs Continued
Table 3-3 Opto Input Signal Conditions
Pin
Number
Signal
Name
Switch = Closed (active) Switch = Open (not active)
X3-9 Enable Drive enabled. Drive disabled.
X3-10 MaI3 Machine Input 3 = Logical 1 Machine Input 3 = Logical 0
X3-11 MaI4 Machine Input 4 = Logical 1 Machine Input 4 = Logical 0
X3-12 Quit Stop positioning mode operation Positioning mode is operating
X3-13 Fault Reset Fault Reset is active (reset control). Fault Reset is not active.
X3-14 Home Flag Home flag = closing (rising) edge Home flag = opening (falling) edge
X3-15 Trigger Trigger = closing (rising) edge Trigger = opening (trailing) edge
X3-16 MaI1 Machine Input 1 = Logical 1 Machine Input 1 = Logical 0
X3-17 MaI2 Machine Input 2 = Logical 1 Machine Input 2 = Logical 0
Signal Name Opto Input Signal Definition
Enable CLOSED allows normal operation.
OPEN disables the control and motor coasts to a stop.
Quit CLOSED cancels any move in progress and the motor will decelerate ( at
parameter MOT.ACC) to rest. This input is edge triggered.
OPEN allows position mode operation.
Fault Reset CLOSED allows the control to be cleared or “Reset” for any of the following four
fault conditions (provided that the cause of the fault has been removed):
$ Overvoltage $ Electronic Fusing
$ Undervoltage $ Resolver Fault
OPEN allows normal operation.
Home Flag Edge triggered input that is used to sense the “Home Position”.
Trigger Rising edge triggered input that initiates a “point-to-point move”. The move is
defined by the machine inputs MaI1-4.
MaI1,2,3,& 4 Four machine inputs are provided. These may be used with the internal PLC
software program. The internal PLC software can cause an event to occur based
on the presence of these inputs.
However, more often these inputs are used to define up to 15 preset positions or
point to point moves. The 16th move is always home. With this method, it is not
possible to use hardware limits (CW and CCW). Therefore, software limits must
be used. Software limits are only active after a homing routine has completed.
Note: Hardware limit switches may be wired in series with the “Enable” input
X3--9. Then if a limit is reached, the control will be disabled.