EasyManua.ls Logo

Banner Q5X Series - One-Point (1-PT) TEACH (Channel 1 Only)

Banner Q5X Series
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© Banner Engineering Corp. www.bannerengineering.com 10
SENSOR PROGRAMMING
If the same target is taught both times, Lo and SPAn flash alternately on the display, the 10 V (20 mA) value is automatically adjusted to maintain
the minimum window size, the new distance quickly flashes four times, and the sensor returns to Run mode.
It is possible to skip teaching the 0 V (4mA) and/or the 10 V (20mA) point and continue to use the existing setting. At the applicable teach step,
when using the push button, hold - for four seconds. The sensor displays SAVE and then flashes the existing value. When using the remote
input, double-pulse the remote input.
3.2.1.2. One-Point (1-PT) TEACH (Channel 1 Only)
One-point TEACH mode defines the span of the analog output. One-point TEACH also defines the 5 V (12 mA) midpoint of the analog output to
center the analog output around a reference target position.
Figure 4: One-Point Window
The sensor must be set to tch = 1-Pt to use the following instructions. To program the sensor using remote input, remote input must be enabled
(inPt = SEt).
1) Present the target at the desired 5 V (12 mA) distance.
2) Start the TEACH mode.
3) Teach the sensor the 5 V (12 mA) midpoint.
Method Action Result
Push Button Press TEACH to teach the target.
The new switch point flashes rapidly and the
sensor returns to Run mode.
Remote Input Single-pulse the remote input.
Method Action Result
Push Button
Present the first target. The sensor-to-target distance must be within the sensor's
range.
The target's measurement value displays.
Remote Input
Method Action Result
Push Button Press and hold TEACH for longer than 2 seconds.
SEt and 5 U flash alternately on the display.
The 1-Pt indicator flashes.
Remote Input No action is required. N/A
Method Action Result
Push Button Press TEACH to teach the target.
The measurement value flashes briefly, and
the sensor returns to Run mode.
Remote Input Single-pulse the remote input.
T
10 V
0 V
Press and Hold
> 2s
Teach 5 V
5 V
5 V
10 V
0 V
5 V
1
Press again
2
3
T

Table of Contents