EasyManua.ls Logo

Banner Q5X Series - Display, Units, and Polarity

Banner Q5X Series
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21 © Banner Engineering Corp. www.bannerengineering.com
SENSOR PROGRAMMING
When lateral entry needs to be considered, the lateral entry response is added to calculate the total response time.
NOTE: The Q5X uses a dynamic measurement rate, so these response times are worst-case.
3.2.12. Output Timing Delays (dLY2)
Use this menu to select the output timing delay to be set.
On and off delay timers can be used together. The default is no delay. For Channel 2, this menu is available when the output is set to light operate
or dark operate.
The number that follows dLY on the display indicates which channel is selected.
oFF—No delay
dLAY—Delay—enables the selection of on and off delay timers
1Sho —One-shot—enables a one-shot, fixed output pulse duration
totL— Totalizer—enables an output after a defined number of targets are counted
Figure 17: Output Timing Delays
When one of the timing delay options is chosen, the sensor returns to the Setup menu and additional options become available to set the param-
eter(s):
dLAY
ond—On delay
oFd—Off delay
1Sho
dt2—One-shot delay timer
For the one-shot delay timer:
LO = On pulse when a target is detected inside of the switch point(s)
DO = On pulse when a target is detected outside of the switch point(s)
totL
dt2—Output duration
tot2—Number of counts before an output change
Table 11:Lateral Entry Response
Lateral entry to the Q5X
Base Measurement
Rate (ms)
Lateral Entry Response (ms)
0.5 3
1.0 5
2.0 15
3.0 25
5.0 50
Output
OFF Delay
ON Delay
Time
1-Shot
ON
OFF
D
D
D
D
D D
(D = 1ms - 90.0s)

Table of Contents