© Banner Engineering Corp. www.bannerengineering.com 28
SENSOR PROGRAMMING
3.5.2. Remote Input Instructions
1) Access the remote input.
2) Lock or unlock the sensor buttons.
3.6. Sync Master/Slave
Two Q5X sensors may be used together in a single sensing application. To eliminate crosstalk between the two sensors, configure one sensor
to be the master and one to be the slave. In this mode, the sensors alternate taking measurements and the response speed doubles.
The master sensor and the slave sensor must be programmed for the same Response Speed and Gain and Sensitivity settings. The master
sensor and slave sensor must share a common power source.
1) Configure the first sensor as the master; navigate: inPt > nASt.
2) Configure the second sensor as the slave; navigate: inPt > SLUE.
3) Connect the gray wires of the two sensors together.
Action Result
Four-pulse the remote input.
The sensor is ready to have the button state defined
and btn displays.
Action Result
Single-pulse the remote input to unlock the sensor. uLoc displays and the sensor returns to Run mode.
Double-pulse the remote input to lock the sensor. Loc displays and the sensor returns to Run mode.
Triple-pulse the remote input to apply the operator lock to the
sensor
0Loc displays and the sensor returns to Run mode
TT
TTT
TT
T
TT
T
TT
T
T
T