Q5X ANALOG SPECIFICATIONS
Discrete Output Distance Repeatability
Beam Spot Size
Beam spot size is calculated as 1.6 times the D4σ measured value
Required Overcurrent Protection
WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations.
Overcurrent protection is required to be provided by end product application per the supplied table.
Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to www.bannerengineering.com.
Certifications
NPN
Output High: ≥ Vsupply - 2.5 V (loads ≤ 50 kΩ)
Output Low: ≤ 2.5 V
White wire specifications per configuration
Q5XKU... models 0–10 V DC, 1000 Ohm minimum
Q5XKI... models 4–20 mA DC, 300 Ohm maximum
Distance (mm) Repeatability
95 to 300 ± 0.5 mm
300 to 1000 ± 0.25%
1000 to 2000 ± 0.5%
2000 to 3000 ± 1.0%
Distance (mm) Size (x × y) (mm)
100 2.6 × 1.5
1000 4.2 × 2.5
2000 6 × 3.6
2000 to 3000 7.8 × 4.7
Supply Wiring (AWG) Required Overcurrent Protection (A) Supply Wiring (AWG) Required Overcurrent Protection (A)
20 5.0 26 1.0
22 3.0 28 0.8
24 1.0 30 0.5