R5906848 /04 DP2K SLP Series 365
Code 20531: LDM 1-3 LLS bank 6 drain voltage too high
For this error the same troubleshooting table can be applied to as for code 20323: LDM 1 LLS bank 1 drain
voltage too high.
Code 20535: LDM 1-3 LLS bank 4 current too high
For this error the same troubleshooting table can be applied to as for code 20335: LDM 1-2 LLS bank 1
current too high.
Code 20539: LDM 1-3 LLS bank 5 current too high
For this error the same troubleshooting table can be applied to as for code 20335: LDM 1-2 LLS bank 1
current too high.
Code 20543: LDM 1-3 LLS bank 6 current too high
For this error the same troubleshooting table can be applied to as for code 20335: LDM 1-2 LLS bank 1
current too high.
Code 20559: LDM 1-3 LLS bank 4 temperature too high
For this error the same troubleshooting table can be applied to as for code 20359: LDM 1-2 LLS bank 1
temperature too high.
Code 20560: LDM 1-3 LLS bank 4 temperature sensor shorted
For this error the same troubleshooting table can be applied to as for code 20360: LDM 1-2 LLS bank 1
temperature sensor shorted.
Code 20561: LDM 1-3 LLS bank 4 temperature sensor open
For this error the same troubleshooting table can be applied to as for code 20361: LDM 1-2 LLS bank 1
temperature sensor open.
Code 20565: LDM 1-3 LLS bank 5 temperature too high
For this error the same troubleshooting table can be applied to as for code 20359: LDM 1-2 LLS bank 1
temperature too high.
Code 20566: LDM 1-3 LLS bank 5 temperature sensor shorted
For this error the same troubleshooting table can be applied to as for code 20360: LDM 1-2 LLS bank 1
temperature sensor shorted.
Code 20567: LDM 1-3 LLS bank 5 temperature sensor open
For this error the same troubleshooting table can be applied to as for code 20361: LDM 1-2 LLS bank 1
temperature sensor open.
Code 20571: LDM 1-3 LLS bank 6 temperature too high
For this error the same troubleshooting table can be applied to as for code 20359: LDM 1-2 LLS bank 1
temperature too high.
Code 20572: LDM 1-3 LLS bank 6 temperature sensor shorted
For this error the same troubleshooting table can be applied to as for code 20360: LDM 1-2 LLS bank 1
temperature sensor shorted.
Code 20573: LDM 1-3 LLS bank 6 temperature sensor open
For this error the same troubleshooting table can be applied to as for code 20361: LDM 1 LLS bank 1
temperature sensor open.