4. Troubleshooting
Code 5290: “dmd blue - temperature too high” (Error)
This er ror code is probably preceded by the warning code 5291: “dmd blue - temperature high”. The sam e troubleshooting table
can be applied.
Code 5291: “dmd blue - temperature high” (Error)
Situation Solution
Blocked fan of the blue channel. Check if the fan can turn freely.
The wire unit of the temperature
sensor (NTC) of the DM D in the blue
channel is disconnected from the
Signal backplane.
Check if the wire unit (reference 3 image 4-24) of the temperature sensor (NTC) of the
DMD in the blue c hannel is connected with the Signal backplane.
Defect temperature sensor which
measures the temperature at the
rear side of the DMD of the blue
channel.
Replace the whole Light Processor Unit. C ontact Barco for further instructions to rep air
the m alfunction Light Processor Unit. It is too critical to r eplace this temperature sensor
in th e eld. The replac ement o f this te mperature sensor must be done at factory or
at an authorized service center.
1
2
3
Image 4-24
DMD temperature sensor connections
Code 5293: “dmd blue - temperature low” (Warning)
Situation Solution
The electronics of the Light
Processor Unit remains off due to a
low DMD temperature.
Make sure that the ambient temp erature is within specs (higher then 10°C (50°F)). Let
the projector acclimate. D o not ignite the lamp, otherwise there is a risk for condensation.
Defect temperature sensor which
measures the temperature of the
DMD of the blue channel.
Replace the whole Light Processor Unit. C ontact Barco for further instructions to rep air
the m alfunction Light P rocessor Unit.
Code 5 294: “dmd blue - temperature sensor open” (Error)
Situation Solution
Wire units of the temperature
sensors are disconne cted from the
Signal Backplane.
Check if the wire units (reference 3 image 4-24) of the temperature sensors are plugged
into their sockets on the Signal Backplane.
Damaged wire unit o f the
temperature sensors (reference
3 image 4-24) w hich m easures the
temperature of the DMD of the blue
channel.
1. Repair the wire unit.
2. If not repairable, replace the whole Light Processor Unit. Contact Barco for further
instructions to repair the malfunction Light Processor U nit.
Defect temperature sensor which
measures the temperature of the
blue c hannel.
Replace the whole Light Processor Unit. C ontact Barco for further instructions to rep air
the m alfunction Light Processor Unit. It is too critical to r eplace this temperature sensor
in th e eld. The replac ement o f this te mperature sensor must be done at factory or
at an authorized service center.
44 R5905043 DP2K-12C/11CX 19/02/2018

Table of Contents

Other manuals for Barco DP2K-C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Barco DP2K-C Series and is the answer not in the manual?

Barco DP2K-C Series Specifications

General IconGeneral
BrandBarco
ModelDP2K-C Series
CategoryProjector
LanguageEnglish

Related product manuals