LED-PRO • User’s Guide 155
_K==oÉãçíÉ=`çåíêçä=mêçíçÅçä
LED-PRO Remote Commands
• Returns: MAC address. xx:xx:xx:xx:xx:xx
S EMAC? (Queries for Ethernet MAC address)
p_^ra=å
• Description: Adjust the Serial Baud Rate.
• Parameters: n - Serial baud rate: n[0-4] 1200 | 2400 | 9600 | 19200 | 38400
• Query:
SBAUD?
Returns the Serial Baud Rate in the format
= n
S SBAUD 0 (Adjusts Serial Baud Rate to 1200)
S SBAUD? (Queries Serial Baud Rate.)
pvp^s
• Description: Saves the System State into non-volatile memory
• Parameters: None
S SYSAV (Saves System State.)
ebim=xçéz
• Description: Displays Command List
• Parameters: op[A..Z] optional command
S Help (Displays command list)
S Help Freez (Displays syntax/parameters for the Freeze command)
il^ao
• Description: Places unit into loader mode. This mode is used to perform field
upgrades
• Parameters: None.
S LOADR (Puts unit into loader mode.)
obpbq
• Description: Factory resets the system and sets all settings to factory defaults.
• Parameters: None
S RESET (Factory reset the LED-PRO™)
t^iipq^ka_v
• Description: Set LED Wall to standby mode
• Usage: WALLSTANDBY [0|1] (0 = enable, 1 = standby)