Three-phase synchronous motors DSC1-045-100
DSC1-045-100
11/2016
Technical alterations reserved
Baumüller Nürnberg GmbH
9
Note:
The supply of cooling fluid must be interrupted to prevent condensation when storing for an extended period. In
addition, at ambient temperatures < 3°C and if the motor has not run for an extended period, drain the cooling
fluid to prevent damage caused by frost. When using anti-freeze you need to consult the manufacturer.
Start
Definition rel.
humidity
Definition of min.
coolant temperature
(section 1.3.2)
T
water
T
ambience
-5K
T
water
> T
min.water
(section 1.3.2)
Derating
referred to
section 1.2.
No
restrictions
2-point
controller
T
on
= 70 °C
T
off
= 50 °C
T
water
25 °C
T
water
25 °C
No
restrictions
T
water
25 °C
No
restrictions
Yes
Yes
Yes
Yes
No
No
No
No
No
Yes