INITIAL SETUP
In the OccluSense
®
-iPad-App select ‘Settings’ and tap
on ‘Initial setup’.
Switch on the handheld.
(press the pink operating button 1)
Your handheld first creates its own network (SSID)
which is shown with the password (WEP) in the
display.
Tap
'Start' in the OccluSense
®
-iPad-App to initiate
the setup process and type the WEP password into
the dialog box.
Confirm the following dialog with
Join’.
WLAN SETUP
Confirm the following dialog with ‘Yes’ to connect the
OccluSense
®
handheld device with your WLAN.
A screen opens with three steps to be performed.
Tap on
‘Next’ to start the process. Now enter your
network name (the last selected SSID is suggested)
and your WLAN password.
Once the data has been entered, tap ‘Next’.
The OccluSense
®
-iPad-App establishes a connection
to the handheld via this network.
A successful connection between the handheld and
the wireless network is indicated by green signal bars
and the first 6 characters of the wireless network in
the upper left corner of the handheld display.
If the connection between the handheld and the
wireless network has failed, the connection status is
indicated on the handheld display by transparent
signal bars. In this case reset the handheld (manual
chapter 19.2) and start the initial setup again.
Quick Start Guide
PREPARATION
Make sure your iPad is connected to your wireless
network and that your wireless network supports the
2.4 GHz (IEEE802.11 b/g/n) frequency. Have your
WLAN password ready.
Install the OccluSense
®
-iPad-App
www.occlusense.com/install
1
2
3
PRI_IFU_OccluSense_QS_EN_002_200110.qxp_Layout 1 Kopie 24.01.20 14:55 Seite 1

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Bausch OccluSense and is the answer not in the manual?

Bausch OccluSense Specifications

General IconGeneral
CategoryDental equipment
ManufacturerBausch
ModelOccluSense
TypeOcclusal analysis system
Sensor Thickness60 μm
FunctionRecords and analyses occlusal forces
UsageDental practices and laboratories

Summary

PREPARATION AND INITIAL SETUP

Install the OccluSense®-iPad-App

App installation instructions from the website.

INITIAL SETUP AND WLAN CONNECTION

Initial Setup and WLAN Connection Steps

Steps for initial setup and connecting to your wireless network.

SYSTEM REGISTRATION AND REQUIREMENTS

DEVICE DESCRIPTION AND USE

SYSTEM FUNCTIONALITY AND DATA FLOW

GENERAL SAFETY PRECAUTIONS

Essential Safety Guidelines

Provides essential safety guidelines for using the OccluSense system.

PREPARATION AND INSTALLATION

Install the OccluSense®-iPad-App

Steps to install the application on an iPad.

BATTERY MANAGEMENT

OCCLUSENSE®-IPAD-APP OVERVIEW

INITIAL APP USAGE MODES

INITIAL SETUP AND CONNECTION

Connecting Handheld to iPad

Steps for initial setup and connecting the handheld to the iPad.

WLAN CONNECTION AND SETUP

Starting the Initial Setup Process

Initiating the setup sequence for the handheld and iPad connection.

HANDHELD CONNECTION TO OCCLUSENSE®

Connecting to the OccluSense® Handheld

Steps to establish connection with the OccluSense® handheld via WLAN.

INTEGRATING INTO EXTERNAL WLAN

Connecting to Your Local WLAN Network

Integrating the handheld into the user's existing wireless network.

SYSTEM REGISTRATION AND DEVICE ADMINISTRATION

Registering the OccluSense System

Mandatory process for full app functionality with the handheld.

HANDHELD DEVICE MANAGEMENT

DEVICE PAIRING PROCEDURES

IT NETWORK REQUIREMENTS FOR LIVE MODE

SAFETY CHECKS AND FUNCTION TESTS

Performing Safety Checks

Daily procedure to ensure the system works correctly.

Conducting the Function Test

Steps to perform a sensor test for system validation.

PATIENT DATA MANAGEMENT

Managing Patient Records Overview

Overview of creating, editing, deleting, and exporting patient data.

PATIENT DATA HANDLING

EDITING AND DELETING PATIENT DATA

RECORDING PROCEDURES

General Recording Preparations

Essential steps and notes before starting a recording.

HANDHELD AND SENSOR PREPARATION

Inserting the OccluSense® Sensor

Instructions on how to properly insert the single-use sensor.

CONNECTION AND WLAN CHECK

SENSOR READINESS AND PATIENT STATUS

Activating a Patient for Recording

Process to select and activate a patient before starting a recording.

PATIENT DATA FOR RECORDING

RECORDING MODES EXPLAINED

Understanding Recording Modes

Details on Live mode, Recording mode, and Live + Recording mode.

RECORDING SETTINGS AND LIVE-MODE

RECORDING MASTICATORY PRESSURE

Inserting Sensor into Patient's Mouth

Guide on correctly positioning the sensor in the patient's mouth.

CONDUCTING RECORDINGS

Starting and Stopping Recordings

Instructions for initiating and concluding recordings based on mode.

FINISHING RECORDINGS AND DISPOSAL

EVALUATION OF RECORDINGS OVERVIEW

Viewing Recorded Data Overview

Introduction to the recording evaluation section and data visualization.

DATA VISUALIZATION OPTIONS

PLAYBACK AND ANALYSIS TOOLS

RECORDING MANAGEMENT AND NOTES

MANAGING AND EXPORTING RECORDINGS

RECORDING PLAYBACK AND COMPARISON

EXPORTING RECORDINGS AND SNAPSHOTS

EXPORTING AS VIDEO AND DATA TRANSFER

APP SETTINGS AND INFORMATION

TROUBLESHOOTING COMMON ISSUES

Basic Troubleshooting Steps

Addressing common problems like damages, resets, and connection loss.

TROUBLESHOOTING TABLES

Troubleshooting the OccluSense App

Solutions for app-related errors and connectivity problems.

Troubleshooting the OccluSense Handheld

Addressing issues with the handheld device, including power and battery problems.

CLEANING AND DISINFECTION

Cleaning and Disinfecting System Components

Procedures for cleaning the handheld, charging station, and test sensor.

COMPONENT CARE AND REUSABILITY

SYSTEM MAINTENANCE AND BATTERY REPLACEMENT

Replacing Handheld Batteries

Step-by-step guide for replacing batteries in the handheld device.

SOFTWARE UPDATES AND NOTICES