© BEKA 201 All rights reserved!6
...a product of BEKA
10.2 Refilling with lubricant
Observe utmost when refilling!cleanless
· Check the level regular and refill if necessary, see chapter start up.
· Please take care to use lubricants that are suitable for the lubricating machine and that also suit the requirements of
the application conditions.
· When ordering from take care that the lubricant is similar to the previousdifferent lubricant manufacturers quality
one. Drain the clean the reservoir completely just to be sure.
11. Repair
If you identified any damage during maintenance, this must be rectified immediately.
Any spare parts required can be found under 15. List of spare parts or under 16. Drawing of spare parts.
Avoid electrostatic discharge! There are electronic components integrated into the devices which might be
destroyed by electrostatic discharge. Observe the safety precautions against electrostatic discharge
according to DIN EN 61340-5-1/-3. Ensure that the environment (persons, workplace and packing) is well
grounded when handling these devices.
11.1 Exchange or retrofit the level switch and/or the angular momentum sensor:
a) Pull off the pump power plug. Demount the pump from the installation location.
b) Remove the cylinder screws (1, Fig. 49).
Fig. 49:
1 (5×)
Attention!
38