4.2 Functions
Device description
5290 / 06/2023 enBENNING PV 1-1+20
4.2.2 Installing the data logger and driver
To read the measured values of the device on a PC via the USBinterface, you must install the
hardware driver and the “BENNINGSOLARDatalogger” software on the PC once.
Requirements
• PC with USB-A port and sufficient storage space
• Download the hardware driver and the “BENNINGSOLARDatalogger” software from the
product page of the device
http://tms.benning.de/pv1-1
• Remove any connected safety measuring lines.
Procedure
1. Install the downloaded hardware driver on your PC.
2. Install the downloaded “BENNINGSOLARDatalogger” software on your PC.
3. Connect the device to your PC using the USBconnecting cable.
The hardware driver is installed automatically on a free COMport and confirms that the new
hardware can be used.
4.2.3 Reading out measured values via the USBinterface
You can read out the measured values of the device on a PC via the USBinterface and store
them as a CSV or TXTfile.
Requirements
• PC with USB-A port and sufficient storage space
• Installed data logger and driver
• Remove any connected safety measuring lines.
Procedure
1. Connect the device to your PC using the USBconnecting cable.
2. Start the “BENNINGSOLARDatalogger” program.
3. Go to “Tools”, click “RefreshPorts” and select the corresponding COMport.
The COMport used can be viewed by means of the Device Manager of your system.
4. Click “Download”.
5. Press and hold the “Measured value memory”key for approx.2 seconds until the download
takes place and the entire measured value memory is read out.
6. Store the read-out measured values as a CSV or TXTfile.
7. To open the measurement series, e.g. via a spreadsheet programme, click “Open”.