iii
APPENDIX B- Related Parameters
Use Related parameters
Accel/Decel time, Pattern Adjustment
DRV-01 [Acceleration Time], DRV-02 [Deceleration Time],
FUN-02 [Acceleration Pattern], FUN-03 [Deceleration Pattern]
Reverse Rotation Prevention FUN-01 [Forward/Reverse Prevention]
Accel/Decel at Continuous Rating Range FUN-02 [Acceleration Pattern], FUN-03 [Deceleration Pattern]
Braking Operation Adjustment
FUN-20 [Starting Mode], FUN-21~22 [DC Injection Braking at Starting]
FUN-23 [Stop Mode], FUN-24~27 [DC Injection Braking],
Operations at freq. Over 60 Hz
FUN-30 [Max. Frequency],
FUN-35 [Frequency High Limit],
I/O-05 [Frequency Corresponding to V1 Max Voltage],
I/O-10 [Frequency Corresponding to I Max Current],
I/O-16 [Frequency Corresponding to P Max Pulse Frequency]
Selecting an Appropriate Output Characteristics for
the Load
FUN-30 [Max. Frequency], FUN-31 [Base Frequency]
Motor Output Torque Adjustment
FUN-32 [Starting Frequency],
FUN-70~71 [Stall Prevention],
AFN-67~69 [Torque Boost],
AFN-40 [Motor Rating]
Output Frequency Limit
FUN-33~35 [Frequency High/Low Limit],
I/O-01~16 [Analog Frequency Setting]
Motor Overheat Protection
DRV-06~09 [Electronic Thermal], AFN-40 [Motor Rating]
I/O-97, 98 [External Thermal Sensor], DRV-05 [Motor Rated Current]
Multi-step Operation
I/O-20~27 [Multi-function Input Define],
DRV-00, 05~07,I/O-31~42 [Multi-step Frequency],
FUN-34~35 [Frequency High/Low Limit]
Jog Operation I/O-30 [Jog Frequency]
Frequency Jump Operation AFN-10~16 [Frequency Jump]
Electronic Brake Operation Timing I/O-74~75 [Frequency Detection], I/O-76~79 [Multi-function Output]
Rotating Speed Display DRV-14 [Motor Rpm], AFN-47 [Motor Rpm Display Gain]
Function Change Prevention AFN-94 [Parameter Lock]
Energy Saving FUN-51~52 [Energy Saving]
Auto Restart Operation after Alarm Stop AFN-20~21 [Auto Restart]
2
nd
Motor Operation APP-20~29 [2
nd
Function]
PID Feedback Operation APP-02~33 [PID Operation]
Adjusting Frequency Reference/Output I/O-01~16 [Analog Frequency Setting]
Defining Multi-function Input terminals I/O-20~27 [Multi-function Input Terminal]
Defining Multi-function Output terminals I/O-76~79 [Multi-function Output Terminal]
Commercial Line<-> Inverter Switchover
I/O-20~27 [Multi-function Input Terminal],
I/O-76~79 [Multi-function Output Terminal]
Frequency Meter Calibration I/O-70~73 [S0/S1 Analog Output]
Operation via Communication with a PC
I/O-90 [Inverter Number], I/O-91 [Communication Speed], I/O-92~93 [Lost
Command]