EasyManua.ls Logo

Bianchi IRIS - Installation: Cleaning and Payment System

Bianchi IRIS
69 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
IRIS
Fig. 6.16
Fig. 6.19
Fig. 6.17
Fig. 6.18
Fig. 6.20
6.5.2 Cleaning of the parts in contact with
food substances
With distributor switched on effect a cleaning of the mixers
pressing the buttons according to what is described in the service
functions so as to eliminate any dirt from the coffee boiler and the
instant boiler.
wash your hands carefully
Move the cup column forward to access the tanks (Fig.6.16).
prepare an anti-bacterial cleaning solution with a chlorine base
(products that can be purchased in pharmacies) following the
concentrations given on the product instruction labels.
remove all the product containers from the distributor (Fig.6.17)
remove the lids from the product containers covers and product
chutes (Fig.6.18). Dip all in the solution previously prepared
remove all the powder chutes, water funnels, mixing bowls
and whippers and silicone tubes and dip these parts also in
the prepared solution (Fig.6.19)
with a cloth soaked with the solution clean the whipper assembly
base (Fig.6.20)
the parts must soak in the solution for the time indicated on
the solutions instruction label.
Recover all the parts, rinse them abundantly, dry them perfectly
and proceed with the re-assembly in the distributor.
For further safety after the assembly of the parts, effect
some automatic cleaning cycles so as to eliminate any
eventual residues.
6.5.3 Payment system installation
The distributor does not have a payment system; any possible
damages to the distributor itself and/or objects and/or people
deriving from its incorrect installation are responsibility of who
installs the payment system,
To install the payment system partially unscrew the three screws
mount the token slot without selector.
Tighten the three screws and mount the selector
connect the coin mechanism to the Master board.
The selectors must be directly connected to the Master board the
and the serial executive system through the interface cable
supplied with the machine.
Then go into programming for the correct settings.
Consult chapter7.0 PROGRAMMING so as to verify setting of
the parameters, that must be coherent with the system used.

Table of Contents