15
IRIS
Fig. 6.2
5 cm
60 cm
60 cm
60 cm
Fig. 6.1
5.0 SAFETY NORMS
ATTENTION!
before using the automatic distributor, read this manual
carefully.
The installation and maintenance operations must be performed
exclusively by qualified technical personnel.
The user must not in any circumstance be able accede to those
parts of the automatic distributor that are protected and require
a tool in order to be accessible.
The knowledge and the absolute respect, from a technical point
of view of the safety instructions and of the danger notices
contained in this manual, constitute the basis for the operation,
in conditions of minimum risk, of the installation, starting and
maintenance of the machine.
Always disconnect the POWER CABLE before
maintenance or cleaning interventions.
ABSOLUTELY DO NOT INTERVENE ON THE MACHINE AND
DO NOT REMOVE ANY PROTECTION BEFORE THE
COOLING OF THE HOT PARTS!
The functional reliability and optimization of machines services
are guaranteed only if original parts are used.
The distributor is not suitable for external installation. The
machine must be connect in dry places, with temperatures
that never go below 1°C it must not be installed in places
where cleaning is done with water hoses (ex. big kitchens).
Do not use water jets to clean the machine.
In order to guarantee normal operation, the machine must be
installed in areas that the environmental temperature is between
a minimum of -1°C and a maximum of +32°C end humidity of
not over 70%.
In order to guarantee a regular operation, always maintain
the automatic distributor in perfect cleaning conditions
Nuova Bianchi S.p.A. declines all responsibility for damages
product to people or belongings in consequence to:
l Incorrect installation
l Inappropriate electrical and/or water connection.
l Inadequate cleaning and maintenance (See section 9.0
MAINTENANCE).
l Not authorized modifications
l Improper use of the distributor
l Not original spare parts
Futhermore verify observance of any other eventual local and
national standards.
6.0 INSTALLATION
6.1 Positioning
As already specified in paragraph 5.0, Safety regulations, the
distributor is not suitable for external installation. The machine
must be connect in dry places, with temperatures that never go
below 1°C it must not be installed in places where cleaning is
done with water hoses(ex. big kitchens.) . It must be installed in
places without danger of explosions or fires.
If positioned near to a wall, there must be a minimum distance
from the wall of at least 5 cm. (Fig.6.1) so as to allow a regular
ventilation. In no case cover the distributor with cloths or similar.
Position the distributor, checking the leveling by means of the
adjustable feet already assembled on the machines (Fig.6.2).
make sure that the distributor doesnt have an inclination of
more than 2 degrees.
WARNING! Do not position the device near inflammable
objects, keep a minimum safety distance of 30 cm.
Nuova Bianchi declines all responsibility for inconveniences due
to the non observance of the above mentioned installation norms.
If the installation is made in safety evacuation corridors make
sure that with the distributor door open there is anyhow sufficient
space to pass by (Fig.6.1).
So as to avoid that the floor gets dirty, due to accidental spilling
of the products, use, if necessary, under the distributor, a protection
sufficiently wide to cover the distributors operating space.
6.2 Connection to the main water supply
Before proceeding with the connection of the distributor to the
water main supply verify the following water characteristics:
that it is drinkable (eventually through an laboratorys analysis
certification)
it has a pressure comprised between 0.5 and 6.5 bar ( if this
should not be the case, use a pump or a water pressure, reducer
according to the case).