8
Boiler type TLM-Pro TLM-Pro MBW PZ25RL PZ 25 RL MBW PZ 32/35 Pro
Boiler class 5 5 5 5 5
Nominal heat output (kW) 17,5 17,5 25,0 25,0 32,2 / 34,9
Eciency full load (%) 91,7 91,7 94,19 94,19 92,39
Eciency part load (%) 92,7 92,7 93,8 93,8 95,76
Max. adjustable boiler temperature (°C) 85 85 90 90 85
Permissible operating pressure (bar) 3 3 3 3 3
Recommended minimum storage volume (l) 525 525 750 750 966 / 1047
CE marking according to Low Voltage Directive
CE CE CE CE CE
Energy eciency class A+ A+ A++* A+ A+
Dimensons
Boiler width (mm) 1155 1155 1305 1305 1305
Boiler depth (mm) 667 667 870 870 945
Total depth (mm) incl. ash box 943 934 1084 1084 1158
Boiler height (mm)
1
1542 1341 1544 1344 1794
Height flue pipe connection (mm)
1
1420 1420 1398 1398 1605
Height forerun (mm)
1
1435 1435 353 353 353
Height return (mm)
1
1435 1435 1080 1080 1324
Vent height (mm)
1
1435 1435 1091 1091 1341
Flue pipe connection diameter (mm) 130 130 130 130 130
Total weight loose (kg) 360 350 376 369 439
Water content (l) 60 60 80 80 120
Reservoir - filling quantity (kg) 40 150 70 187 134
Ash box usable (l) 15 15 15 15 15
Connections
Forerun (Inch) 1 1 1 1 1⁄
Return (Inch) 1 1 1 1 1⁄
Ventilation for boiler (Inch) ⁄ ⁄ ⁄ ⁄ ⁄
Boiler draining (Inch) ⁄ ⁄ ⁄ ⁄ ⁄
Flow resistance on the heating water sideFlow resistance on the heating water side
ΔT= 20 K (mbar) 5 5 32,9 32,9 103
ΔT= 10 K (mbar) 20 20 131,7 131,7 412
Exhaust gas values
Exhaust gas temperature at full load (C°) 120 120 120 120 120
Exhaust gas temperature at part load (C°) 100 100 100 100 100
Exhaust gas mass flow at full load (g/s) 9,0 9,0 15,0 15,0 22,0
Exhaust gas mass flow at part load (g/s) 3,0 3,0 5,5 5,5 5,8
Co
2
at full load (Vol%) 13,5 13,5 13,5 13,5 13,5
Co
2
at part load (Vol%) 10,0 10,0 10,0 10,0 10,0
Necessary flue draught full load (Pa)
2
8 8 8 8 8
Necessary flue draught part load (Pa) 4 4 4 4 4
Electrical power consumption
Standby (W) 20 20 20 20 20
Filling turbine (W) 1340 0 1340 0 1340
Grate cleaning (W) 65 65 65 65 65
Prefill (W) 75 75 75 75 75
Ignite (W) 1034 1034 1034 1034 1034
Continuous operation Partial load / Full load (W) 50 / 80 50 / 80 50 / 80 50 / 80 50 / 80
Minimum distance masonry
To the front (mm) 1000 1000 1000 1000 1000
To the back (mm) 200 200 500-900 500-900 500-900
Left to masonry (mm)
3
100-300 100-300 100-300 100-300 100-300
Right to masonry (mm) 400-900 400-900 400-900 400-900 400-900
Minimum room height (mm) 2000 2000 2200 2200 2200
Insert dimension
At least (mm) 750 750 750 750 750
*) Combined label (boiler+room thermostat)
1) excl. adjustable feet, adjustment range up to 55 kW 15–30 mm
2) From 10 Pa, a draught limiter must be used below the firing connection
3) Recommendation at least 250 mm, otherwise increased maintenance eort (costs)
PLANING FOLDER PELLET BOILER
Individual values are based on the standard type test. These may deviate in practice.
4. TECHNICAL DATA