0,535 0,00 0,00
1
0,000 0,00 0,000,535
NET
1
2
2,000 0,00 0,000,535
NET
1
2
Operating instruction EC IIOperation
6 − 6
6.107.98.5.01.44
6.7 Tare functions
6.7.1 Tare balancing with the tare unknown
_______________________________________________________________________
An unknown tare weight (empty container) is a non−PLU−related tare
which is to be weighed and tared.
− Scales having a weighing range below 10 kg allow the full range
to be tared.
− Scales the weighing range of which exceeds 10 kg allow taring of
up to max. 9,995 kg (max. 4−digit) only (country−related).
− The tared value will be subtracted from the total weighing range.
− A taring command is directly executed only when the weight
indication has stabilized.
− If an unknown tare value has been tared by means of key <Tara>
this value may not be overwritten by a known tare (preset tare,
PLU tare).
− After an unknown tare value has been balanced, a PLU call with
the PLU tare is possible. The PLU tare will then, however, be
ignored.
_______________________________________________________________________
Unknown tare
Weighing of a PLU item into an empty container with an unknown tare weight.
Fig.: Unknown tare
Place the empty container on the scales.
he weight display
1
indicates the weight of
the empty container, e.g.: ”0.535” kg.
Press the <Tare> key.
The tare−display
2
shows the weight of the empty
container, ”0.535” kg.
The weight display
1
shows zero.
Fill the empty container with the product.
The weight display
1
indicates the net weight
of the product ”2.000” kg.
The tare−display
2
shows the weight of the
empty container, ”0.535” kg.
6