Operating instruction EC II Programming
7 − 17
6.107.98.5.01.44
Programming overview
Product maintenance Setting option Menu see
page
Set the PLU unit price PLU number
Unit price
Pr 110 7 − 2
Set the PLU tare value PLU number
tare in grams
Pr 113 7 − 3
Delete individual PLU
products
PLU number Pr 171 7 − 4
Delete the complete
PLU product pool
All saved products (PLU) are being dele-
ted.
Pr 172
7 − 4
Configuration Setting option Menu see
page
10−key keypad
for entering
unit price or PLU input
0 Unit price input via keypad
Switch to PLU no. input
1 PLU no. Input via keypad
Switch to unit price input
2 PLU no.
(It is not possible to switch)
Pr 512 7 − 5
Fixed
Key function
0 Fix unit price
1 Fix tare
2 Fix unit price and tare
Pr 514 7 − 6
Set zeros in price input 0 no set zero 0,00
1 one set zero 0,00
2 two set zeros 0,00
3 three set zeros 0,00
Pr 522 7 − 6
Control display ligh-
ting
00 Manual switch on/off
01−99 Automatic switch on/off
01=1sec./ 99=99sec.
Pr 530 7 − 7
Turn−off function 00 Scale is not turned off
01−99 Turn−off time after min.
Pr 531 7 − 8
Battery charging func-
tion
0 No charging
1 Automatic charging
2 Trickle charging
Pr 532 7 − 8