Operating instruction EC IIProgramming
7 − 16
6.107.98.5.01.44
Activate/deactivate turn−off function in mains operation Pr792
In menu Pr 792 the turn−off function is activated or locked in Pr531 for mains operation.
See also Pr 531 page 7 − 8.
0 = Turn−off function during mains operation inactive.
1 = Turn−off function during mains operation active.
On−period of power−saving mode (SLEEP) Pr793
If a turn−off time >10 minutes is set in menu Pr531, the ADC is put into power−saving mode
after approx. 3 minutes as standard. This time can be set as you wish via the Pr793 menu.
See also Pr 531 page 7 − 8.
03 = Time in minutes, (00−99)
_______________________________________________________________________
If a time of 00 minutes is set, power−saving mode is not executed.
If a time is set that is greater than the turn−off time in Pr531,
power−saving mode is also not executed.
_______________________________________________________________________