37
9.4 Smart Reg Operaon
9.4.1. ON/OFF Knob
The Smart Reg knob has two hard-stops for OFF and ON posions. OFF mode is actually a sleep/standby
mode. A fully charged baery would be half depleted in about a year if le connected to Nomad with the knob set
to OFF. Therefore, always disconnect the baery for long-term storage.
With the Smart Reg knob set to ON, Nomad is constantly powering and checking its sensors waing to
detect breathing or pumping commands and control the pump motor. With the baery connected and the knob set
to ON, a fully charged baery would be half depleted in about two days even if Nomad is not pumping.
With the Smart Reg knob set to the ON posion, Nomad is factory-set for an inhalaon eort
approximately equivalent to SCUBA regulators. The inhalaon eort may be re-calibrated by qualied technicians
if necessary, such as in the event of replacement of Smart Reg components, using the procedures in Secon 14.3
on Page 50.
Because it is possible to stop air ow with the knob seng, we placed Nomad’s ON/OFF knob at the
locaon-of and within the control of the diver instead of at the surface.
Lung over-expansion injuries and deaths have occurred in SCUBA divers caused by inhaling compressed air at
depth and then breath-holding while ascending. While Nomad’s maximum depth is limited, Nomad divers are
sll breathing compressed air at depth which may lead to lung over-expansion if the diver does not exhale prop-
erly during ascent. Always breathe normally while diving and do NOT hold your breath while ascending. Refer to
the BLU3 Online Dive Training Course for further informaon and instrucon.
With Nomad powered on and Smart Reg knob set to ON, certain condions such as shocks and vibraons can
cause the pump to run unsupervised while out of water. Allowing Nomad to run for extended periods out of
water will cause overheang and may cause permanent damage, resulng in reduced air output, contaminated
air output, and out-of-air hazards. Always leave the knob in the OFF posion during storage and transport and
preferably with baery disconnected. Always place Nomad in the water while in use.
Rotang the Smart Reg Knob into the OFF posion while underwater will result stop air ow resulng in out-of-
air hazards. The Knob must be rotated to the ON posion before the diver aempts to breathe underwater.
9.4.2 Inhale or Exhale - Do NOT hold your breath.
Nomad’s behaviors are controlled by soware acng upon input from sensors in the Smart Reg. In order for Nomad
to funcon properly and for ulmate safety of the user, the user shall always maintain an open airway by either
inhaling or exhaling. The diver shall never hold their breath.
Nomad may pump sporadically if a user is holding their breath underwater; this can serve as a reminder to either
inhale OR exhale, but to never hold your breath.