Part II: System Commands
PERIMETR PART ? (COMMAND + 8)
D1260 Owner’s Manual
© 2003 Bosch Security Systems 50410C
PERIMETR PART ? (COMMAND + 8)
Partially Turn On the Perimeter
Description
This function is used to turn on the perimeter of your building while selected portions of the perimeter remain turned
off. Perimeter points that are not secure (faulted) when this function is entered are automatically bypassed and are not
included in the system. This function does not turn on the interior of your building. Entry/exit delays are provided with
this arming command.
Use this function in residential systems to turn on the front of your house while the interior and the rear perimeter doors
are left turned off, giving you freedom of movement between the house and patio.
In commercial systems, when you need access to the large overhead doors to receive deliveries, using this function will
allow you to keep the rest of the building perimeter armed.
Using Perimetr Part:
1. Ensure your command center shows idle disarmed
text.
Before using this function, decide which points are to be left turned off. Fault the points (doors and
windows) by leaving them open. The points must remain open until after the exit delay time expires.
2.
Press the COMMAND key.
3. The display shows *System Command*.
4.
Press the 8 key.
Note: If you prefer, you may use the Command Menu in place of steps 2 and 3 to initiate this function.
Press the Menu> soft key to enter the Command Menu,
then press Next> soft key repeatedly
until you reach the PERIMETR PART ?> prompt then press the
adjacent soft key.
5. The display shows.
# is the number of seconds remaining, counting down
from 10 seconds, before the system is armed.
6. When exit delay time expires and the system turns on,
the display shows:
7.
When performing a COMMAND 8 and no points are faulted or if the points return to normal
before the exit delay time expires, the system is turned on as in COMMAND 3.