Table 1: Programming Features
Program Feature or
Option
Permitted in
UL864? (Yes/No)
Possible Settings
Settings Permitted in
UL864
Auto Test
Frequency
Yes
1) 4 h
2) 12 h
3) 24 h
4) 7 days
5) 28 days
6) Disabled
1) 4 h
2) 12 h
3) 24 h
Program Relay
Yes
1) Release on Trouble
2) Activate on Ground
Start
1) Release on Trouble
AC Fail Delay
Yes
1) Wait for DC
2) Wait Delay Time
0-24 h
2) Wait Delay Time 1-3 h
Phone Line Monitor
for Each Line
Yes
0) No
1) Yes
1) Yes
Response Time
Yes
1) Fast (0.5 sec)
2) Programmed
1) Fast (0.5 sec)
2) 1-9 sec