1 689 989 185 2018-03-24| Robert Bosch GmbH
Product description | EPS 205 | 49 en
Connecting return adapter to connection panel
458825_4
ko
X20
1
2
3
4
Fig. 29: Connecting return adapter to connection panel
1 EPS 205 connection panel
2 Hose 1 680 712 360
3 Return adapter
4 CRIN
Return adapter with threaded connection
For CRIN with screw connection M8 x 1.
458808-5Ko
3
1
2
Fig. 30: Fitting return adapter with threaded connection
Screw the plug-in nipple (Fig.30, item1) and
adapter (Fig.30, item3) with flat sealing ring
10.2x13.4mm (Fig.30, item2) together and
secure.
Return adapter for CRIN with threaded connection
(screw connection M8 x 1)
458826
-12_Ko
1
Fig. 31: Return adapter with threaded connection
1 Return adapter