1 689 989 185 2018-03-24| Robert Bosch GmbH
68 | EPS 205 | Maintenanceen
6.3 Spare and wearing parts
Designation Order number
Connection adapter with
adapter nut M12
<)
and
adapter nut M14
<)
1 687 023 641
Spare parts set for connection adapter with
O-ring (2x) and support ring (2x)
1 680 210 150
Sealing plug
<)
1 683 370 038
Inlet connector
12 O-rings 9.5 x 2
<)
1 683 386 166
1 680 210 143
Inlet filter 1 687 434 067
Adapter for check valve 1 683 350 904
Spare parts set for inlet filter with flat
sealing ring, filter element and O-ring
(6x each)
<)
1 687 001 974
Knurled nut 9 mm
<)
1 683 373 086
Knurled nut 7 mm
<)
1 683 373 087
Hose
<)
1.5 m
(for draining test oil tank)
1 680 712 283
Flushing drain
<)
1 680 712 293
Hose (injection)
<)
1 680 712 362
Hose (return)
<)
1 680 712 287
Hose (return)
<)
1 680 712 360
Pen 1 683 083 004
Adapter cable set for injector test
<)
(1 684 465 841 and 1 684 465 842)
1 687 010 171
Intake filter for test oil tank (3x)
<)
1 685 431 015
Flowmeter pipe filter
<)
1 687 434 051
Toothed belt
<)
1 684 736 022
Guard 1 685 510 238
Hose
<)
(CRI Piezo return inlet) 1 680 703 078
Hose
<)
(CRI Piezo return outlet) 1 680 703 079
DVD drive 1 687 023 846
Adapter cable
<)
for CRI Piezo 1 684 465 669
Adapter cable
<)
for CRI Piezo 1 684 465 671
Adapter cable
<)
for CRIN 1 684 465 843
Adapter cable
<)
for CRI 1 684 465 841
Adapter cable
<)
for CRI 1 684 465 842
O-Ring 12 x 2
<)
for injection chamber 1 680 210 123
O-Ring 9 x 3
<)
for injection chamber 1 680 210 132
O-Ring 7 x 4
<)
for injection chamber 1 680 210 124
Strainer
<)
(2x) for changeover valve 1 680 002 020
High-pressure hose assembly
<)
1 687 010 369
1)
<)
Wearing parts
1)
Customer service performs maintenance and exchanges.
6 ±0,5 Nm
6 ±0,5 Nm
30 ±2 Nm
458886-77_Ko
1
2
4
3
5
Fig. 48: Replacing the strainer
1 Hose fitting
2 Strainer
3 Banjo bolts
4 Strainer bracket
5 Hose assemblies
6. Remove hose assemblies (fig. 48, item 5) from the
hose fittings (fig. 48, item 1).
7. Remove both banjo bolts (fig. 48, item 3) at the
strainer brackets (fig. 48, item 4) of the changeover
valve (fig 47, item4).
8. Clamp the strainer bracket in a vice.
9. Remove both hose fittings from the strainer bracket
using an open-ended wrench.
10. Remove strainer (fig. 48, item 2) from both strainer
brackets and locate the new strainers in the strainer
brackets in their correct position.
11. Tighten the hose fittings (hose fitting with seal)
to the strainer brackets using a torque wrench
(30Nm±2Nm).
12. Remove the strainer bracket from the vice.
13. Secure strainer bracket to changeover valve using
banjo bolts with seals using a torque wrench
(6Nm±0.5Nm).
14. Slide the hose assemblies onto the hose fittings and
secure them.
15. Screw the ground cable to the housing cover.
16. Secure the housing cover using fastening screws
(8x).
" Strainers are replaced.