EasyManua.ls Logo

Bosch EPS 205 - 5.4.5 CRI Piezo test procedure

Bosch EPS 205
636 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 689 989 185 2018-03-24| Robert Bosch GmbH
Operation | EPS 205 | 61 en
5.4.5 CRI Piezo test procedure
DANGER – Risk of fatal injury from
electromagnetic fields
The high voltages at the CRI Piezo (charging
of the actuators) and at the adapter cables
are a source of potential fatal injury for
persons wearing pace-makers.
Anyone wearing a pace-maker is not
allowed to perform "Common Rail Injector
(CRI Piezo)" testing.
! Do not check any damaged and/or severely corroded
components.
458881-273_Ko
Fig. 41: Block diagram of CRI Piezo connection
1 CRI Piezo return inlet
2 CRI Piezo return outlet
3 Test connection for return quantity and adapter with check valve
4 Test connection for injected fuel quantity with inlet filter
5 CRI Piezo socket
6 Injection chamber
7 CRI Piezo
8 Connection adapter
9 High-pressure hose
i Use is to be made of the accessory set
1 687 010 400 (special accessory) for non-Bosch
injectors.
i The prerequisites to be observed when checking
and adjusting CRI Piezo can be found in the test
instructions for CRI Piezo in ESI[tronic] 2.0. These
test instructions do not form part of the scope of
delivery. ESI[tronic] 2.0 can not be installed on the
EPS 205.
Procedure:
1. Clean the CRI Piezo (see Sec. 5.3).
i Perform the "leak test" before fitting the injection
chamber (Fig. 41, item 6) on the component.
2. Attach the CRI Piezo (Fig. 41, item 7) to the clamp
(Fig.3, item 3).
! To avoid twisting and premature wear, do not
connect the high-pressure hose directly to the
CRIPiezo.
3. Connect the high-pressure hose with the connection
adapter (Fig. 41, item 8, 9) to the CRI Piezo.
! The connection adapter must be tightened to
a torque of between 25 Nm and 30 Nm. If the
connection between the connection adapter and the
CRI Piezo is leaking, the screw connection is not to
be re-tightened. In the event of a leak, unfasten the
connection again, clean the sealing surface and re-
connect the connection adapter applying the correct
tightening torque.
4. Connect the hose 1 680 703 078 to the return of
the CRI Piezo and to the "CRI Piezo return inlet"
(Fig. 41, item 1).
5. With a Bosch piezo CRI, plug the adapter with check
valve into the "test connection for return quantity"
(fig. 41, item 3).
! Do not use the adapter with check valve with third-
party piezo CRIs.
6. Connect the hose assembly 1680703079 to the
"piezo CRI return outlet" (fig. 41, item 2) and the
adapter with check valve or, with a third-party piezo
CRI, to the "test connection for return quantity"
(fig.41, item 3) of the EPS 205.
7. Connect the injector-specific adapter cable
(1684465669, 1684465671) to the CRI Piezo
and to the "Socket" (Fig. 41, item 5).
! Route the injector-specific adapter cable such that it
does not come into contact with the hot hoses.

Table of Contents

Related product manuals