PRAESENSA LCD call station | PRA-CSLD, PRA-CSLW | en 141
Bosch Security Systems B.V. Installation manual 2019.11 | V1.00 |
Power transfer
Power over Ethernet (PoE 1‑2)
Nominal DC input voltage
Standard
48V
IEEE802.3af (mode B)
Power consumption
Call station (general use)
Call station (alarm use)
Per call station extension (indicators off / on)
4.2W
5.4W
0.1W / 1.0W
Input voltage tolerance 37 to 57VDC
Supervision (PRA-CSLD)
Supervision
Microphone
Audio path
Controller continuity
PoE (1‑2)
Current
Pilot tone
Watchdog
Voltage
Supervision (PRA-CSLW)
Supervision
Microphone
Audio path
Press‑to‑talk switch
Controller continuity
PoE (1‑2)
Impedance
Pilot tone
Impedance
Watchdog
Voltage
Network interface
Ethernet
Protocol
Redundancy
100BASE‑TX,
1000BASE‑T
TCP/IP
RSTP
Audio/control protocol
Network audio latency
Audio data encryption
Control data security
OMNEO
10ms
AES128
TLS
Ports 2
Environmental
Climatic conditions
Temperature
Operating
Storage and transport
-5 to +50°C
(23 to 122°F)
-30 to +70°C
(-22 to 158°F)
Humidity (non‑condensing) 5 to 95%
Air pressure (operating) 560 to 1070hPa