Logamatic EMS – 6 720 801 387 (2011/05)
29
System settings (Service menu – Settings)
6
6.2 Hybrid
B Turn the rotary selector to the left until Hybrid is selected.
B Press to select Hybrid.
The SETTINGS\HYBRID menu is opened
Menu item Input range Standard setting
Other
information
Is there a buffer in the
system?
Yes, No no
Triggering of boiler / heat
pump depends on:
Environmental factors,
costs, switching threshold,
environment and costs
Environment
Energy price ratio for
electricity / fossil fuel
0.0 to19.9 3.3
What is the primary energy
factor for the fossil fuel?
0.0 to 5.0 1.1
What is the primary energy
factor for the electrical
energy?
0.0 to 5.0 2.6
What should the dual-mode
switching threshold be?
-20 °C to +20 °C +6 °C
How is the pump on the
HM10 integrated
hydraulically?
serial, parallel serial
By what amount of time
should the boiler switch-in
be delayed?
5 to 120 minutes
Temperature difference for
delayed boiler switch-in?
1K to 99K
Table 12 Navigator for Service menu\Settings\Hybrid
You can find explanations on the settings in the documents for the hybrid system.