Reset
Logamatic EMS – 6 720 801 387 (2011/05)
52
9
9 Reset
The RESET menu allows you to reset
all parameters to basic setting
1)
the fault list
1)
,
the service message
2)
and
the hours run
2)
.
B Turn the rotary selector to select a menu, e.g error list.
B Press buttons to switch into the display, e.g Would you like to reset the error list?
B Press buttons and turn rotary switch to set the display to Yes.
The reset is implemented after you release the button.
An appropriate message is shown during the reset; this will close automatically
B Once reset is complete: confirm the new message by pressing any key.
1) With boilers with UBA1.x, DBA or UBA-H3 only all the parameters of the RC35 are reset, but not the
parameters of the automatic firing units of.
2) This function is not possible with boilers with UBA1.x or DBA
After resetting to the basic position, you must reset the parameters according to the
system configuration.