System settings (Service menu – Settings)
Logamatic EMS – 6 720 801 387 (2011/05)
32
6
Heating curve
Std. tmp. ( – 10 °C) 30 °C to 90 °C 75 °C
(radiator,
convector)
45 °C
(floor)
The value in brackets is the setting
for the minimum outside
temperature (Æ page 31). Setting
only if the control mode is set to
“outside temperature
compensated”(Æ page 36).
Max flow temp. Radiators,
convectors: 30 °C
to 90 °C.
1)
Underfloor heating:
30 °C to 60 °C
Radiators,
convectors:
75 °C
Underfloor
heating:
50 °C
Setting only if the control mode is
set to“outside temperature
compensated”(Æ page 36).
Enter the maximum
flow temperature:
Setting only if the control mode is
set to“room temperature
compensated”(Æ page 36).
Min flow temp. 5 °C to 70 °C 5 °C Setting only if the control mode is
set to“outside temperature
compensated”(Æ page 36)
Enter the minimum flow
temperature:
Setting only if the control mode is
set to“room temperature
compensated”(Æ page 36).
Rm. tmp. offset -5.0 K to +5.0 K 0.0 K Offset of heating curve.
Setting only if the control mode is
set to “outside temperature
compensated”(Æ page 36).
Enter the maximum room
influence:
0 K to 10 K 3 K Setting only if the control mode is
set to “outside temperature
compensated”(Æ page 35).
Which reduction mode
should be implemented?
Outdoor
compensation
mode,
reduced mode,
room compensation
mode (only if RC35
or RC2x have been
allocated to the
heating circuit),
switch-off mode
Outdoor
setback
mode
Night reduction
(Æ page 37)
Menu item Input range
Standard
setting Other information
Table 14 Navigator for service menu of SETTING\HEATING CIRCUIT 1