3 Ratings and Dimensions
3.1 Fe UL Ratings and Dimensions in Common
Description Symbol Unit Data
Listing according to UL standard (UL) – – UL 508 C
UL files (UL) – – NMMS.E328841
Enclosure – – Open type
Pollution degree (UL) – – 2
Ambient temperature with nominal data (UL)
T
amax
°C 40
Ambient temperature with reduced nominal da‐
ta (UL)
T
amax_red
°C 50
Minimum distance on the top of the device
1)
d
top
mm 150
Minimum distance on the bottom of the de‐
vice
2)
d
bot
mm 150
Horizontal spacing on the device
3)
d
hor
mm 50
Short circuit current rating (UL) SCCR A rms
5000
(0K75 to 90K0)
42000
(110K to 160K)
Rated input voltage, power (UL)
4)
U
LN_nenn
V
3 x AC
380...480
Tolerance rated input voltage (UL) % -15...+10
Input frequency (UL)
f
LN
Hz 50...60
Tolerance input frequency (UL) Hz ± 5
Field wiring material (material; conductor tem‐
perature; class)
– –
Copper;
60/75°C
(0K75 to 22K0)
Copper; 75 °C
(30K0 to 160K)
Output voltage (UL)
U
out
V
Corresponding
to input voltage
Output frequency range (UL)
5)
f
out
Hz 0...650
Fig.3-1: Fe - UL Ratings and Dimensions in Common
DOK-RCON01-REX*F*UL***-IN01-EN-P
Rexroth Frequency Converters
Bosch Rexroth AG
Ratings and Dimensions
29/65