● Operating panel cable for cabinet mounting
4.3 Transport of the Components
Ambient and operating conditions-Transport
Description Symbol Unit Value
Temperature range
T
a_tran
℃ -25…70
Relative humidity – % 5…95
Absolute humidity –
g/m
3
1…60
Climate category (IEC 721) – – 2K3
Moisture condensation – – not allowed
Icing – – not allowed
Fig.4-1: Transport conditions
4.4 Storage of the Components
Damage to the components caused by long storage
periods!
Some components contain electrolytic capacitors which may deteriorate during storage.
When storing these components for a long period of time, remember to operate them
once a year:
● Run frequency converter EFC 3600 under power U
LN
for at least 1 hour.
● For more information of electrolytic capacitors, please contact service.
Ambient and operating conditions-Storage
Description
Symbol Unit Value
Temperature range
T
a_store
℃
-25…55
Relative humidity – % 5…95
Absolute humidity –
g/m
3
1…29
Climate category (IEC 721) – – 1K3
Moisture condensation – – not allowed
Icing – – not allowed
Fig.4-2: Storage conditions
Bosch Rexroth AG
Delivery and Storage
DOK-RCON03-EFC-3600***-IT01-EN-P
Rexroth Frequency Converter EFC 3600
22/235