Risks of damage to the components!
CAUTION
Only operate the components in their allowed mounting positions.
Allowed mounting position of the components:
Only the mounting position G1 is allowed for EFC 3600. Please refer to the figure be‐
low.
a Mounting surface g Direction of gravitational force
G1 Normal mounting positions. The natural
convection supports the forced cooling
air current. This avoids the generation of
pockets of heat in the component.
G2 180° to normal mounting position
G3 Turned by 90° from vertical to horizontal
mounting position
G4 Bottom mounting; mounting sur‐
face on bottom of control cabinet
G5 Top mounting; mounting surface at top of
control cabinet
Fig.5-4: Frequency converter mounting position
DOK-RCON03-EFC-3600***-IT01-EN-P
Rexroth Frequency Converter EFC 3600
Bosch Rexroth AG
Mounting and Installation
27/235