EasyManua.ls Logo

Bosch Rexroth Sytronix FcP 5020 - Page 12

Bosch Rexroth Sytronix FcP 5020
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Code Name Setting range Default Min. Attri.
F1.11 Flow command source
0: Depend on the value of F1.14
1: Analog input (positive / nega-
tive)
2: Communication
3: Select by digital input (F1.14
shows status)
0 - Stop
F1.12 Flow command digital setting 0 0...5,000 rpm 400 1 Run
F1.13 Flow command digital setting 1 0...5,000 rpm 400 1 Run
F1.14 Flow command selection
0: Flow command digital setting 0
1: Flow command digital setting 1
0 - Run
F1.15 Motor type
0: Others
1: MOT-FC_HOY
1 - Stop
F1.16 Motor power level
0: No selection
1...5: Reserved
6: 1.5 kW
7: 2.2 kW
8: 3 kW
9: 4 kW
10: 5.5 kW
11: 7.5 kW
12: 11 kW
13: 15 kW
14: 18.5 kW
15: 22 kW
16: 30 kW
17: 37 kW
18: 45kW
19: 55 kW
20: 75 kW
21: 90 kW
0 - Stop
F1.20
CytroPac parameter initializa-
tion
0: No selection
1: CytroPac basic
2: CytroPac advanced
3: CytroPac premium
4: myCro
0 - Stop
Bosch Rexroth AG
Initial Start Up
FcP 5020
8/83
DOK-RCON03-FCP5020****-QU04-EN-P

Table of Contents