Code Name Setting range Default Min. Attri.
F1.21 CytroPac parameter display
0: No selection
1: CytroPac basic
2: CytroPac advanced
3: CytroPac premium
4: myCro
0 - Stop
F2.06
Pressure feedback correspond-
ing to 5V, 10V or 20mA
0.1...1,000.0 bar 100.0 0.1 Stop
F2.07
Pressure feedback null offset in
V or mA
0.0...5.0 V, mA
4.0
(mA)
0.1 Stop
F2.10 Pressure sensor type
0: Others
1: HM20-2X/10-C
2: HM20-2X/50-C
3: HM20-2X/100-C
4: HM20-2X/160-C
5: HM20-2X/250-C
6: HM20-2X/315-C
7: HM20-2X/400-C
8: HM20-2X/630-C
9: Other 4...20 mA pressure sen-
sor
10: Reserved
11: HM20-2X/10-H
12: HM20-2X/50-H
13: HM20-2X/100-H
14: HM20-2X/160-H
15: HM20-2X/250-H
16: HM20-2X/315-H
17: HM20-2X/400-H
18: HM20-2X/630-H
19: Other 0...10 V pressure sen-
sor
3 - Stop
Tab. 5-1: Parameter list of initial start up
FcP 5020
Bosch Rexroth AG
Initial Start Up
DOK-RCON03-FCP5020****-QU04-EN-P
9/83