Code Name Setting range Default Min. Attri.
F4.21 Minimum pressure command limit 0.0...[F4.22] bar 5.0 0.1 Stop
F4.22
Maximum pressure command lim-
it
[F4.21]...1,000.0 bar 250.0 0.1 Stop
F4.23 Minimum flow command limit 0...[F4.24] rpm 200 1 Stop
F4.24 Maximum flow command limit [F4.23]...5,000 rpm 3,000 1 Stop
F4.25
Acceleration time hydraulic soft
start
0.1...6,000.0 s 5.0 0.1 Run
F4.28
Two points / double pump selec-
tion
0: Two points pump
1: Double pump
0 - Stop
F4.29 Pump logic selection
0: Positive
1: Negative
0 - Stop
F4.30 Pump Vg1 0...1,000 ccm 0 1 Stop
F4.31 Pump Vg2 0...1,000 ccm 0 1 Stop
F4.32
Upper pressure difference switch-
ing threshold
0.0...350.0 bar 15.0 0.1 Stop
F4.33
Lower pressure difference switch-
ing threshold
0.0...350.0 bar 10.0 0.1 Stop
F4.34
Speed switching threshold adjust-
ment
0.1...1.0 0.9 0.1 Stop
F4.35 Pump power 0.00...315.00 kW 0.00 0.01 Stop
F4.36 Pump thermal protection speed 0…5,000 rpm 500 1 Stop
F4.37
Pump thermal protection time
constant
0…6,000 s 0 1 Stop
F4.38 Effective Pump Vg 0...1,000 ccm 0 1 Read
F4.39 Master / slave switch source
0: Depend on the value of
F4.03
1: Digital input
2: Communication
0 - Stop
F4.40
Slave pump speed command low-
er limit
-5,000...5,000 rpm 0 1 Run
F4.41
Master / slave pump mode switch
delay
0...500 ms 100 1 Stop
F4.45
Pressure boost for drop compen-
sation
0.0...1,000.0 bar 0 0.1 Run
F4.46
Pressure reduce for overshoot
compensation
-1,000.0...0.0 bar 0 0.1 Run
F4.50 Oil filter warning / error delay time 0...1,000 s 60 1 Run
F4.51 Warning hours of oil change 0...60,000 hours 36,000 1 Run
F4.52 Error hours of oil change 0...60,000 hours 40,000 1 Run
Bosch Rexroth AG
FcP 5020 Parameter List
FcP 5020
72/83
DOK-RCON03-FCP5020****-QU04-EN-P