Code Name Setting range Default Min. Attri.
F4.53 Oil in operation time 0...60,000 hours 0 - Read
F4.54 Reset oil in operation time 0...1 0 1 Run
F4.70 Drive start level via AI (for myCro) 0.0...20.0 V, mA 14.2 0.1 Run
F4.71 Drive stop level via AI (for myCro) 0.0...20.0 V, mA 10.4 0.1 Run
F4.72 Oxygen too high warning level 0.0...20.0 V, mA 15.5 0.1 Run
F4.73 Oxygen too high warning delay 0.0...100.0 hours 4.0 0.1 Run
F4.74 Pressure too low warning level 0.0...300.0 bar 100.0 0.1 Run
F4.75 Pressure too low warning delay 0.0...100.0 s 60.0 0.1 Run
Tab. 8-4: Parameter list of group F4