Version 4.0
2024-03-27
BOSCHE Weighing Systems
Page 66
Weighing Terminal EWI / MWI Function menu (advanced functions) | 5
PRINT3
Print 2: Data transmitted to printer LP- 50
Data format:
N<CR><LF>
A0,1,0,0,1,1,B,"01.04.22 14:39:04"<CR><LF>
LO0,26,380,3<CR><LF>
A0,33,0,0,1,1,B,"Net: Tare: Gross:"<CR><LF>
A0,58,0,0,1,1,B," 0.0Kg 0.0Kg 0.5Kg "<CR><LF>
LO0,83,380,3<CR><LF>
P1<CR><LF>
PRINT4
Print 4: Data transmitted to printer HLS
Data format:
<CAN>_<CAN>_<CAN>_<CAN>_<CAN>_<CAN>_<CAN>_<CAN>_<CAN>_<CA
N>_<CAN>_<CAN>_<CAN>_<CAN>_<CAN>_<CAN>_<CAN>_<CAN>_<CAN>_
<CAN>_<ESC>_@<ESC>_{1<ESC>_R<STX>_<ESC>_32<LF>
<ESC>_ <STX>_<ESC>_!1Tare: 0.0 Kg<CR><LF>
Net:0.0 Kg<CR><LF>
Gross:0.5 Kg<CR><LF>
Time:14.41:17<CR><LF>
Date:01.04.22<CR><LF>
<CR><LF>
<CR><LF>
<CR><LF>
PRINT5
Print 5: Data transmitted to printer TPS 143
Data format:
<ESC>_@<ESC>_{0<ESC>_R<STX>_<ESC>_32<LF>
<ESC>_ <STX>_<ESC>_!1Tare: 0.0 Kg<CR><LF>
Net:0.0 Kg<CR><LF>
Gross:0.5 Kg<CR><LF>
Time:14.42:58<CR><LF>
Date:01.04.22<CR><LF>
<CR><LF>
<CR><LF>
<CR><LF>
<CR><LF>
<CR><LF>
<CR><LF>
<CR><LF>
<CR><LF>
<CR><LF>
<CR><LF>
<CR><LF>
<CR><LF>
<CR><LF>