Maintenance and Use of the Terminal
ATTENTION
Only use soft, dry or slightly damp cloths to clean the terminal; do not use any chemical products.
Use the terminal only with the pen provided or with similar instruments. Do not use tools, pens or other
sharp instruments which may damage the display and compromise operation.
Do not expose the LCD screen to direct sun light.
Gateway OH/GW
Device that lets you interface the network of terminals connected on Bus MultiMaster (MM) with BPT electri-
cal automation and Brahms anti-intrusion security B2 and C4 systems.
For the part for interface with BPT electrical automation systems, you can connect:
- without Bus NH-RBB repeater
- 1 power supplier OH/A.01 and 38 modules of BPT generic electrical automation;
- with Bus NH-RBB repeater
- 1 power supplier OH/A.01 and 78 modules of BPT generic electrical automation.
Each gateway is counted as 1 home automation node.
NOTE. In connections with NH-RBB repeaters, provide the following connection sequence:
- OH/A.01+38 modules+NH-RBB+40 BPT electrical automation modules.
For the anti-intrusion security part, the B2 and C4 control units are connected via a serial interface.
Technical Features
Power supply 12÷24 V DC
• Absorption:
70 mA at 12 V DC
50 mA at 18 V DC
45 mA at 24 V DC
Operating temperature: from 0
°C
to +35 °C.
Dimensions: low-profile 4-unit module for installation on DIN rail.
ManTecnico_MithoPlus IT_GB 2484561 61ManTecnico_MithoPlus IT_GB 2484561 61 18-06-2008 11:50:0918-06-2008 11:50:09