Brooks Automation
278580 Revision A 93
LF80C ZeniD RFID Reader 7 Operation
Product Manual 7.3 Operation of SECS Protocol
Parameter 0 (0x00) Gateway ID
The gateway ID is a part of the device ID. The BROOKS SECS-I reader
works simultaneously as a gateway and as a reader (CIDRW with integrated
head).
It is the "lower message ID" in the message header.
00 .. 255
Default: Last two characters of hex serial number
The default gateway ID corresponds to parameter 8 (TARGETID low byte).
For more details see
Parameter 8 (0x08).
36 0x24
Lock membrane keyboard
37 0x25
MID area
38 0x26
Test after software reset
39 0x27
Transmitter level (write mode)
40 0x28
Transponder load duration (write
mode)
41 0x29
Delay time between read cycles
42 0x2A
CarrierIDOffset
43 0x3B
CarrierIDLength
44 0x2C
FixedMID
45 0x2D
MIDFormat
99 0x63
Customer code
123 0x7B
Fine version
No. (dec) No. (hex) Parameter name