7 Operation LF80C ZeniD RFID Reader
7.3 Operation of SECS Protocol Product Manual
Parameter 1 (0x01) Baudrate
Data transmission rate to the SECS-Host
3: 300 Baud
6: 600 Baud
12: 1,200 Baud
24: 2,400 Baud
48: 4,800 Baud
96: 9,600 Baud
192: 19,200 Baud
200: 38,400 Baud
201: 57,600 Baud
202: 115,200 Baud
Default: (192) 19,200 Baud (see accompanying letter of the reader)
Parameter 2 (0x03) Inter-character timeout T1
1 .. 100 1/10 s
Default: (5) 0.5 s
Parameter 3 (0x03) Block protocol timeout T2
2 .. 250 1/10 s
Default: (10) 1 s
Parameter 4 (0x04) Reply timeout T3
1 .. 120 1 s
Default: (45) 45 s
Parameter 5 (0x05) Inter-block timeout T4
This parameter is ineffective if the used messages are not larger than one
block.
1 .. 120 1 s
Default: (45) 45 s
Parameter 6 (0x06) Retry limit RTY
Number of times a question or message is to be repeated.
0 .. 31
Default: (0)