EasyManua.ls Logo

Brooks LF80C - Page 122

Brooks LF80C
180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Brooks Automation
110 278580 Revision A
7 Operation LF80C ZeniD RFID Reader
7.3 Operation of SECS Protocol Product Manual
S1F17: REQUEST ON_LINE (host -> reader, reply)
The reader is requested to change the communication status to online.
S1F17 W. *Header only
S1F18: ONLINE ACKNOWLEDGE (reader -> host)
Acknowledge.
S1F18
<B[1]ONLACK>.
Equipment control S2F0: ABORT TRANSACTION (reader <-> host)
Used instead of an expected reply to abort a transaction. Function 0 is
defined in every stream and has the same meaning in every stream.
S2F0 W. * Header only
S2F13: EQUIPMENT CONSTANT REQUEST (host -> reader,
reply)
The host requests an attribute from the reader.
S2F13 W
<L[1]
<U1[1] ECID>
>.
S2F14: EQUIPMENT CONSTANT DATA (reader -> host)
The reader sends the requested attribute to the host.
S2F14
<L[1]
<U1[1] ECV>
>.
S2F15: NEW EQUIPMENT CONSTANT SENT (host -> reader,
reply)
The host changes a reader attribute.
S2F15 W
<L[1]
<L[2]
<U1[1] ECID>
<U1[1] ECV>
>
>.