LF80C ZeniD RFID Reader 7 Operation
Product Manual 7.3 Operation of SECS Protocol
S2F16: NEW EQUIPMENT CONSTANT ACKNOWLEDGE (reader -
> host)
The reader acknowledges the setting of the reader parameter.
S2F16
<B[1] EAC>.
S2F19: RESET SENT (host -> reader, reply)
The host requests the reader to reset the hardware and software.
If a heartbeat time is set (
Î
Parameter 9 (0x09)), the reader sends an
S1F1 message when the reset is finished.
The power-up reset requires a few seconds.
S2F19 W
<B[1] RIC>.
S2F20: RESET ACKNOWLEDGE (reader -> host)
The reader acknowledges the reset.
This message is only displayed in case of a power-up reset (RIC=2).
S2F20
<B[1] RAC>.
Material status S3F0: ABORT TRANSACTION (reader <-> host)
Used instead of an expected reply to abort a transaction. Function 0 is
defined in every stream and has the same meaning in every stream.
S3F0 W. * Header Only
S3F5: CASSETTE FOUND SENT (reader -> host, reply)
The reader sends the information that a cassette was detected by the
presence sensor.
This message is sent only if a sensor is connected and activated (see
Î
Parameter 27 (0x1B) and
Î
Parameter 26 (0x1A)).
S3F5 W.
<L[2]
<B[1] MF>
<B[1] PTN>
>.
S3F6: CASSETTE FOUND ACKNOWLEDGE (host -> reader)
The host acknowledges the cassette found message.
S3F6
<B[1] ACKC3>.