EasyManua.ls Logo

Brooks LF80C - Page 127

Brooks LF80C
180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Brooks Automation
278580 Revision A 115
LF80C ZeniD RFID Reader 7 Operation
Product Manual 7.3 Operation of SECS Protocol
Exception handling S5F0: ABORT TRANSACTION (reader <-> host)
Used instead of an expected reply to abort a transaction. Function 0 is
defined in every stream and has the same meaning in every stream.
S5F0 W . * Header only
S5F1: GATEWAY READER ALARM REPORT SEND (reader ->
host, reply)
The reader reports all errors to the host.
S5F1 W
<L[3]
<B[1] ALCD > * alarm code byte
<B[1] ALID > * alarm ID
<A[MAX 40] ALTX > * alarm text
>.
S5F2: ALARM REPORT ACKNOWLEDGE (host -> reader)
The host acknowledges an alarm.
S5F2
<B[1] ACKC5>.
System errors S9F1: UNRECOGNIZED DEVICE ID (reader -> host)
The device ID in the message block header does not correspond to
expected device ID.
S9F1
<B[10] MHEAD > .
S9F3: UNRECOGNIZED STREAM TYPE (reader -> host)
The reader does not recognize the stream type in the message block
header.
S9F3
< B[10] MHEAD > .
S9F5: UNRECOGNIZED FUNCTION TYPE (reader -> host)
The reader does not recognize the function number in the message block
header.
S9F5
< B[10] MHEAD > .
S9F7: ILLEGAL DATA (reader -> host)
The reader does not recognize the data in the message.
S9F7
< B[10] MHEAD > .